l Chemistry Measurements: 11 , 12, 14 parameters available
l RBC Morphological Analysis: automatic analysis and generated with diagrams and images |
l Physical measurement: color, turbidity measured by RGB sensor; specific gravity measured by refractometer; conductivity measured by electrode method l Chemistry measurement: colorimetry l Microscopy measurement: Machine Vision Technology (Automated Morphological Microscopy) |
Advantages l Unique design with both Chemistry and Microscopy measurements integrated, which makes both measurements done by sampling oncel Measurement Modes Optional: chemistry, microscopy, or chemistry+microscopy. Physical Measurement
l Independent PMC module automatically measures color, turbidity, specific gravity and conductivity. Chemistry Measurement
l Patent strip feeding device Microscopy Measurement l Made strictly according to ISLH Recommended Reference Procedure for the Enumeration of Particles in Urinel Uncentrifuged urine sample at cutoff concentration level of 3-5 cell/ul are detectable l precise morphological analysis of RBC helps to determine the source of heπ1atuna l Standardized and confirmatory report with both images and diagrams available. Pop ups indicate on-screen verification with no need to redo the measurement l Self-learning function continuously improves the recognition accuracy. l Un-centrifuged urine microscopy reference values available l CFDA approved quality controls of four levels available
|
(2024 January , latest feature ; version 2)
l Throughput:
Chemsitry speed : 240 samples per hour ( 3 chambers)
Microscopy > 140 samples per hour ( 3 chambers)
Hybrid : >140 samples per hour ( 3 chambers)
l Min. sample volume: 2 ml ( hybrid mode)
l Sample preparation: native sample
l Built-in barcode reading: Yes
l Counting Chamber: 1-3 ( as per modular requirement)
l Detection rate: ≥98% for sample at concentration of 5 cells/ul
l Accuracy: For chemistry measurement, comparing to reference solution, results are within tolerance of one level or no false positive and negative; for microscopy measurement, ≥95%
l Repeatability: For chemistry measurement , CV≤ 1%; for microscopy measurement, CV ≤7%
l Carryover: At concentration of 4600-5400 cells/ul≤ 1cell/ul,At concentration of 9200-10800 cells/ul≤2cells/ul
l Verification: Full-view field images + segmented images
l Report: comprehensive results with images and diagrams
l Sampler: loading capacity of 60 samples
l Strip tank capacity: 200 strips
l STAT: available
l Data interface: bidirectional
l LIS/HIS connection: available
l Results storage: ;;. 200,000 results
l Dimensions: 825×650×545mm' Weight: 73kg